Inverter Ducted models

SUPERIOR COMFORT

The Daikin Inverter range of ducted units are ideal for multiple rooms or zoned applications. The Daikin inverter has increased power at start-up, so the desired temperature is reached quicker. You can also dramatically reduce the humidity levels in matter of minutes with the Program Dry setting. Daikin Inverter ducted systems can handle extreme temperatures and has certified operation in temperatures from a freezing -15°C in heating to a searing 46°C in cooling.

Daikin Inverter technology provides the comfort of temperature control, reduced energy consumption and quiet indoor and outdoor units.

FEATURES OF DAIKIN INVERTER DUCTED SYSTEMS

  • MEPS compliant
  • Requires only single phase power supply which can lower installation costs (Models FBQ50/60/71B).
  • Inverter compressor control for enhanced comfort levels.
  • Quiet yet powerful operation.
  • Instant computerised self-diagnostic system, reducing diagnostic time in the unlikely event of a breakdown.
  • Hot start. In the heating mode and after defrost, the indoor heat exchanger is warmed up to a preset temperature first before the indoor fan switches to the set fan speed. This ensures that only warm air is discharged from the air conditioning unit.
  • Auto restart after power failure.

FEATURES OF INVERTER INDOOR UNITS

  • Compact Design -- height and width reduced to allow indoor units to be installed in limited ceiling space.
  • Built to exceed compliance with relevant AS/NZS standards.
  • High strength galvanised steel casing.
  • High efficiency (Hi-X) heat exchanger coils that further add to energy savings.
  • Microprocessor-controlled operation and monitoring.

FEATURES OF INVERTER OUTDOOR UNITS

  • Quiet operation
  • Swing compressor for higher efficiency and reliability.
  • Soft starter is unnecessary, making electrical installation work much simpler.
  • Certified operation down to -15°C in heating and up to 46°C in cooling.
  • Up to 30m of refrigerant piping allows flexibility of location.
  • PE coated heat exchangers for greater protection against corrosion.

 

FBQ50BV1A FBQ60-71BV1A RXS50FAVMA RXS71FVMA
FBQ50BV1A FBQ60-71BV1A RXS50FAVMA RXS71FVMA

 

INDOOR UNIT
FBQ50BV1A FBQ60BV1A FBQ71BV1A
 
OUTDOOR UNIT
RXS50FAVMA RXS60FAVMA RXS71FVMA
 
Rated Capacity
Cool (kW) 5.0 5.7 6.7
Heat (kW) 6.0 7.0 8.2
Capacity Range
Cool (kW) 1.7-5.6 1.7-7.0 2.3-8.0
Heat (kW) 1.7-7.0 1.7-8.0 2.3-10.0
Power Input (Rated)
Cool (kW) 1.98 2.23 2.57
Heat (kW) 1.93 2.26 2.67
C.O.P.
C/H 2.53/3.11 2.56/3.10 2.61/3.07
Air Flow Rate (Rated)
l/s 217 300 300
Indoor Sound Level (@1.5m)
dBA 33 34 34
ESP Setting
  LO/STD/HI LO/STD/HI LO/STD/HI
Indoor Fan Speeds
  HI/LO HI/LO HI/LO
Dimensions
(H x W x D)
Indoor (mm) 300 x 700 x 800 300 x 1000 x 800 300 x 1000 x 800
Outdoor (mm) 735 x 825 x 300 735 x 825 x 300 770 x900 x 320
Weight
Indoor (kg) 34 41 41
Outdoor (kg) 48 48 71
Power Supply
Ø/V/HZ 1 phase, 220-240, 50Hz
Compressor type
  Hermetically Sealed, Swing Type
Refrigerant
  R410A
Refrigerant Control
  Electronic Electronic Electronic
Refrigerant Pipe Size
Liq (mm) 6.4 (Flared) 6.4 (Flared) 6.4 (Flared)
Gas (mm) 12.7 (Flared) 12.7 (Flared) 15.9 (Flared)
Drain Pipe Size
  VP25 (OD 32, ID 25)
Supply Air Conn.
mm 215 x 460 (Flange) 215 x 760 (Flange) 215 x 760 (Flange)
Return Air Conn.
mm 228 x 533 (Flange) 228 x 833 (Flange) 228 x 833 (Flange)
Max Actual Pipe Length
m 30 30 30
Max Level Difference
m 20 20 20
Pre Charged Length
m 10 10 10
Outdoor Operating Range
Cool (°CDB) 10 to 46 10 to 46
Heat (°CWB) -15 to 18 -15 to 18
Outdoor Sound Level (H) @ 1 Metre from front of unit
Pressure dBA (C/H) 47/48 49/49 52/52
EPA Sound Power Level
(dBA) 62 63 66

NOTES

  • Rated Capacity is measured in accordance with AS/NZS 3823.1.2.
  • The cooling (or heating) capacities will be reduced below the rated values as the outside temperature approaches the maximum (or minimum) temperature limits.
  • Factory Fitted soft starter is standard on single phase R(Y)71LUV192 & RY100LUV1S.
  • Outdoor sound pressure levels are determined in accordance with JIS8615.
  • Out door sound power levels are determined in accordance with EPA regulations (excludes R(Y)125LU ~ R(Y)250LU).
  • The Daikin 5 year warranty applies only to products in the product brochure purchased and installed in Australia or New Zealand. It does not apply to any non Daikin components used in the installation (eg. ducting, air outlets, zone motors etc.).
  • Due to ongoing product development, specifications are subject to change without notice.

New Inverter Ducted models

FDYQ71FV1 FDYQ100-125-160KV1 RZQ100-125-160KV4A
FDYQ71FV1 FDYQ100-125-160KV1 RZQ100-125-160KV4A

 

INDOOR UNIT
FDYQ71FV1 FDYQ100KV1 FDYQ125KV1 FDYQ160KV1
  FDYQ71FV1 FDYQ100KV1 FDYQ125KV1 FDYQ160KV1
OUTDOOR UNIT
RZQ71FV4A RZQ100KV4A RZQ125KV4A RZQ160KV4A
  RZQ71FV4A RZQ100KV4A RZQ125KV4A RZQ160KV4A
Rated Capacity
Cool (kW) 7.1 10.0 12.5 15.5
Heat (kW) 8.3 12.1 14.9 16.3
Capacity Range
Cool (kW) 3.2-8.0 5.0-11.2 5.7-14.0 6.2-15.5
Heat (kW) 3.5-9.0 5.1-12.5 6.0-16.0 6.2-18.0
Power Input (Rated)
Cool (kW) 2.58 3.09 4.17 5.74
Heat (kW) 2.64 3.46 4.30 4.55
C.O.P.
C/H 2.75/3.14 3.24/3.49 3.00/3.46 2.7/3.58
Air Flow Rate (Rated)
l/s 590 815 925 1070
Indoor Sound Level (@1.5m)
dBA 45 46 48 51
ESP Setting
  STD/HI STD/HI STD/HI STD/HI
Indoor Fan Speeds
  HI/LO HI/LO HI/LO HI/LO
Dimensions
(H x W x D)
Indoor (mm) 360 x 1168 x 869 360 x 1478 x 899
Outdoor (mm) 770 x 900 x 320 1170 x 900 x 320
Weight
Indoor (kg) 48 59 64 66
Outdoor (kg) 65 99
Power Supply
Ø/V/HZ 1 phase, 220-240, 50Hz
Compressor type
  Hermetically Sealed, Swing Type Hermetically Sealed, Scroll Type
Refrigerant
  R410A
Refrigerant Control
  Electronic Expansion Valve
Refrigerant Pipe Size
Liq (mm) Ø9.5 (Flared) Ø9.5 (Flared)
Gas (mm) Ø15.9 (Flared) Ø15.9 (Flared)
Drain Pipe Size
  ID 25mm, OD 32mm ID 25mm x OD 32mm
Supply Air Conn.
mm 751 x 243 (Flange) 1152 x 243 (Flange)
Return Air Conn.
mm 1 x 400 (Oval) 2 x 400 (Oval)
Max Actual Pipe Length
m 50 75
Max Level Difference
m 30 30
Pre Charged Length
m 30 30
Outdoor Operating Range
Cool (°CDB) -5 to 46 -5 to 46
Heat (°CWB) -15 to 15.5 -15 to 15.5
Outdoor Sound Level (H) @ 1 Metre from front of unit
Pressure dBA (C/H) 48/50 48/51 50/52 50/52
Night Quiet Mode (dBA) 47 45
EPA Sound Power Level
(dBA) 66 65 - -

NOTES

  • Rated Capacity is measured in accordance with AS/NZS 3823.1.2.
  • The cooling (or heating) capacities will be reduced below the rated values as the outside temperature approaches the maximum (or minimum) temperature limits.
  • Factory Fitted soft starter is standard on single phase R(Y)71LUV192 & RY100LUV1S.
  • Outdoor sound pressure levels are determined in accordance with JIS8615.
  • Out door sound power levels are determined in accordance with EPA regulations (excludes R(Y)125LU ~ R(Y)250LU).
  • The Daikin 5 year warranty applies only to products in the product brochure purchased and installed in Australia or New Zealand. It does not apply to any non Daikin components used in the installation (eg. ducting, air outlets, zone motors etc.).
  • Due to ongoing product development, specifications are subject to change without notice.

 

FDYQ180/200MV1 FDYQ250MV1 RZYQ7/8/10PY1
FDYQ180-200MV1 FDYQ250MV1 RZYQ7/8/10PY1

 

INDOOR UNIT
FDYQ180MV1 FDYQ200MV1 FDYQ250MV1
  FDYQ180MV1 FDYQ200MV1 FDYQ250MV1
OUTDOOR UNIT
RZYQ7PY1 RZYQ8PY1 RZYQ10PY1
  RZYQ7PY1 RZYQ8PY1 RZYQ10PY1
Rated Capacity
Cool (kW) 18.0 20.0 25.0
Heat (kW) 20.0 22.4 28.0
Capacity Range
Cool (kW) 10.8-20.0 12.0-22.4 15.0-28.0
Heat (kW) 12.0-22.4 13.4-25.0 16.8-31.5
Power Input (Rated)
Cool (kW) 5.68 6.43 8.90
Heat (kW) 5.63 6.27 8.28
C.O.P.
C/H 3.17/3.58 3.11/3.57 2.81/3.38
Air Flow Rate (Rated)
l/s 1180 1200 1400
Indoor Sound Level (@1.5m)
dBA 51 51 51
ESP Setting
  STD/HI STD/HI STD/HI
Indoor Fan Speeds
  HI/LO HI/LO HI/LO
Dimensions
(H x W x D)
Indoor (mm) 500 x 1210 x 910 500 x 1210 x 910 500 x 1410 x 910
Outdoor (mm) 1680 x 930 x 765
Weight
Indoor (kg) 77 79 98
Outdoor (kg) 205 205 249
Power Supply
Ø/V/HZ 3/415/50 3/415/50 3/415/50
Compressor type
  Hermetically Sealed, Scroll Type
Refrigerant
  R410A
Refrigerant Control
  Electronic Electronic Electronic
Refrigerant Pipe Size
Liq (mm) 9.5 (Brazed) 9.5 (Brazed) 9.5 (Brazed)
Gas (mm) 19.1 (Brazed) 19.1 (Brazed) 22.2 (Brazed)
Drain Pipe Size
  BSP 3/4 inch internal Thread (OD 32.7mm)
Supply Air Conn.
mm 827 x 376 (Flange) 827 x 376 (Flange) 939 x 376 (Flange)
Return Air Conn.
mm 918 x 350 (Flange) 918 x 350 (Flange) 1118 x 350 (Flange)
Max Actual Pipe Length
m 150 150 150
Max Level Difference
m 50 (40 if outdoor unit is below)
Pre Charged Length
m 0 0 0
Outdoor Operating Range
Cool (°CDB) -5 to 43
Heat (°CWB) -20 to 15.5
Outdoor Sound Level (H) @ 1 Metre from front of unit
Pressure dBA (C/H) 57/57 57/57 58/58

NOTES

  • Rated Capacity is measured in accordance with AS/NZS 3823.1.2.
  • The cooling (or heating) capacities will be reduced below the rated values as the outside temperature approaches the maximum (or minimum) temperature limits.
  • Factory Fitted soft starter is standard on single phase R(Y)71LUV192 & RY100LUV1S.
  • Outdoor sound pressure levels are determined in accordance with JIS8615.
  • Out door sound power levels are determined in accordance with EPA regulations (excludes R(Y)125LU ~ R(Y)250LU).
  • The Daikin 5 year warranty applies only to products in the product brochure purchased and installed in Australia or New Zealand. It does not apply to any non Daikin components used in the installation (eg. ducting, air outlets, zone motors etc.).
  • Due to ongoing product development, specifications are subject to change without notice.

New Fixed Speed Ducted models

FDYQN71FV1 FDYQN100-125-160KV1 RQ100-125-160KV4A
FDYQN71FV1 FDYQN100-125-160KV1 RQ100-125-160KV4A

 

INDOOR UNIT
FDYQ71FV1 FDYQ100KV1 FDYQ125KV1 FDYQ160KV1
  FDYQ71FV1 FDYQN100KV1 FDYQ125KV1 FDYQ160KV1
OUTDOOR UNIT
RZQ71FV4A RZQ100KV4A RZQ125KV4A RZQ160KV4A
  RQ71FV4A RQ100KV4A RZQ125KV4A RZQ160KV4A
Rated Capacity
Cool (kW) 7.1 10.9 13.5 15.3
Heat (kW) 8.3 11.8 14.2 16.3
Power Input (Rated)
Cool (kW) 2.73 3.97 4.8 5.86
Heat (kW) 3.60 3.50 4.30 4.80
C.O.P.
C/H 2.60/2.31 2.75/3.37 2.81/3.30 2.61/3.40
Air Flow Rate (Rated)
l/s 590 815 925 1070
Indoor Sound Level (@1.5m)
dBA 45 46 48 51
ESP Setting
  STD/HI STD/HI STD/HI STD/HI
Indoor Fan Speeds
  HI/LO HI/LO HI/LO HI/LO
Dimensions
(H x W x D)
Indoor (mm) 360 x 1168 x 869 360 x 1478 x 899
Outdoor (mm) 770 x 900 x 320 1170 x 900 x 320
Weight
Indoor (kg) 48 59 64 66
Outdoor (kg) 65 99
Power Supply
Ø/V/HZ 1 phase, 220-240, 50Hz
Compressor type
  Hermetically Sealed, Swing Type Hermetically Sealed, Scroll Type
Refrigerant
  R410A R410A
Refrigerant Control
  Electronic Electronic Electronic Electronic
Refrigerant Pipe Size
Liq (mm) Ø9.5 (Flared) Ø9.5 (Flared)
Gas (mm) Ø15.9 (Flared) Ø15.9 (Flared)
Drain Pipe Size
  ID 25mm, OD 32mm ID 25mm x OD 32mm
Supply Air Conn.
mm 243 x 751 (Flange) 1152 x 243 (Flange)
Return Air Conn.
mm 1 x 400 (Oval) 2 x 400 (Oval)
Max Actual Pipe Length
m 50 50
Max Level Difference
m 30 30
Pre Charged Length
m 30 30
Outdoor Operating Range
Cool (°CDB) -5 to 46 -5 to 46
Heat (°CWB) -10 to 15.5 -10 to 15.5
Outdoor Sound Level (H) @ 1 Metre from front of unit
Pressure dBA (C/H) 49/51 51/55 51/53 52/54
EPA Sound Power Level
(dBA) 66 67 - -

NOTES

  • Rated Capacity is measured in accordance with AS/NZS 3823.1.2.
  • The cooling (or heating) capacities will be reduced below the rated values as the outside temperature approaches the maximum (or minimum) temperature limits.
  • Factory Fitted soft starter is standard on single phase R(Y)71LUV192 & RY100LUV1S.
  • Outdoor sound pressure levels are determined in accordance with JIS8615.
  • Out door sound power levels are determined in accordance with EPA regulations (excludes R(Y)125LU ~ R(Y)250LU).
  • The Daikin 5 year warranty applies only to products in the product brochure purchased and installed in Australia or New Zealand. It does not apply to any non Daikin components used in the installation (eg. ducting, air outlets, zone motors etc.).
  • Due to ongoing product development, specifications are subject to change without notice.

Inverter Technology

Conventional air conditioners operate at a fixed speed, delivering a fixed amount of cooling and heating. While trying to maintain a set temperature they operate on the "stop and start" principle.

A Daikin inverter is a much more advanced technology that operates differently. It works like the accelerator of a car, gently increasing or decreasing power. It reaches the desired temperature quicker and maintains it without wild fluctuations.

That means uninterrupted comfort and significant energy savings.

Whole-House Comfort

Superior intelligence. The new Daikin Super Inverter air conditioners are so intelligent that, when in Auto Mode, they consider all of the factors that affect your comfort such as outdoor and indoor temperatures.

They then remember your preferred setting in similar conditions and make subtle adjustments to the temperature so you feel totally comfortable. Because this intelligence eliminates excessive cooling and heating it also achieves energy savings.

Program Dry reduces humidity levels to keep you comfortable when things become a little sticky!

Because the Daikin Super Inverter has increased power at start-up, the desired temperature is reached quickly.

Guaranteed operation at temperature extremes. Daikin Super Inverter Ducted systems handle the most extreme temperatures. Operation is guaranteed from a freezing -10°C to a searing 46°C.

Energy Saving

The new Daikin Super Inverter air conditioners use considerably less energy than non-inverter conventional units.

Daikin's advanced technology is incorporated into a number of the Super Inverter Ducted's components which result in significantly lower energy costs.


(Click image to enlarge)

More powerful Neodymium magnets in the new Reluctance DC Compressor help generate more power using less energy. Outstanding energy savings are achieved, particularly when operating in the low-frequency zone. Daikin received the Japanese Electric Science and Promotion Prize for its innovative design.

Quiet Operation

The new Daikin Super Inverter Outdoor Ducted units are so quiet they are barely audible. You won't find a quieter ducted unit than a Daikin Super Inverter.

This extra quiet operation is possible because of innovative design improvements to key components.

Night Quiet Mode. In this mode, the speed of the outdoor fan and compressor is automatically reduced when the unit deduces that it is night time. This provides neighbour-friendly operation at night. The Night Quiet Mode can also be timer operated.

DAIKIN'S SUPER INVERTER OUTDOOR
UNITS INCORPORATE 148 JAPANESE
PATENTED FEATURES.


  1. Reluctance DC Compressor
  2. DC Sine-Wave Inverter
  3. Heat divide type heat exchanger
  4. New super cooling circuit
  5. DC fan motor
  6. Compressor linked fan control
  7. Hybrid aerofoil fan.
    High-flared bell mouth.
    Super aero grille.
  8. Intelligent precise temperature control
 
about us what is
airconditioning?
quality equipment customer help technical 
information
testimonials office
locations
free design
 & quote
Head Office & Showroom: 109A Conyngham St, Frewville, South Australia 5063
Phone: 08 8379 7177             Fax: 08 8379 7166
© 2004 Affordable Airconditioning