Inverter Split Airconditioning
From switch on, the air conditioner operates at full power to reach the desired temperature as quickly as possible. Once the desired temperature is reached the power is precisely controlled and supplied only as required.

 The frequency of the power is regulated to match the outside and indoor air temperature, set temperature and room size, so the air conditioning capacity automatically varies from very strong to gentle.

Inverter Heating & Cooling

Daikin E Series
The E Series
R-410AAn innovative sense of style

External Unit FTXG25E
FTXG25EVMA Cooling Capacity 2.5kW Heating Capacity 3.4kW
FTXG35E
FTXG35EVMA Cooling Capacity 3.5kW Heating Capacity 4.2kW

HEATING & COOLING

INDOOR

 

FTXG25EVMAW

FTXG35EVMAW

FTXG25EVMAS

FTXG35EVMAS

OUTDOOR

 

RXG25EVMA

RXG35EVMA

RXG25EVMA

RXG35EVMA

Rated Capacity
Cool (kW) 2.5 3.5 2.5 3.5
Heat (kW) 3.4 4.2 3.4 4.2
Capacity Range
Cool (kW) 1.3-3.0 1.4-3.8 1.3-3.0 1.4-3.8
Heat (kW) 1.3-4.5 1.4-5.0 1.3-4.5 1.4-5.0
Indoor Airflow Rate(Hi)
Cool (l/s) 128 135 128 135
Heat (l/s) 150 160 150 160
Indoor Fan Speed
  5 steps, quiet and automatic
Energy Label/
Star Ratings
Cool 6 5 6 5
Heat 6 5.5 6 5.5
Front Panel Colour
  Matt crystal white Matt crystal silver
Power Supply
  1 phase, 220-240V, 50Hz
Power Input
(Min-rated-max
Cool (kW) 0.30-0.62-0.95 0.30-1.06-1.29 0.30-0.62-0.95 0.30-1.06-1.29
Heat (kW) 0.29-0.82-1.42 0.31-1.13-1.56 0.29-0.82-1.42 0.31-1.13-1.56
C.O.P.
C/H 4.03/4.15 3.30/3.72 4.03/4.15 3.30/3.72
Dimensions
(H x W x D)
Indoor (mm) 275 x 840 x 150 275 x 840 x 150
Outdoor (mm) 550 x 765 x 285 550 x 765 x 285
Weight
Indoor (Kg) 9
Outdoor (Kg) 32
Compressor Type
  Hermetically sealed swing type
Refrigerant Type
  R410A
Max Pipe Length
(m) 20
Max Level Difference
(m) 15
Refrigerant Pipe Size
Liquid (mm) Ø6.4
Gas (mm) Ø9.5
Drain (mm) Ø18.0
Operating Range
(outdoor temp)
Cool (CDB) 10 to 46°
Heat (CWB) -15 to 20 °
Indoor Sound
Level (H/L/SL)
Cool (dBA) 38/30/27 39/32/29 38/30/27 39/32/29
Heat (dBA) 38/30/27 39/31/28 38/30/27 39/31/28
Outdoor Sound
Level (H/L)
Cool (dBA) 46/43 47/44 46/43 47/44
Heat (dBA) 47/44 48/45 47/44 48/45
EPA Sound Power Level
Outdoor (dBA) 62 63 62 63

NOTES

  1. The Rated Capacity, Power Input and Running Current are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1
  2. The cooling (or heating) output capacity will be reduced below the rated value as the outdoor temperature approaches the maximum (or minimum) outdoor temperature operating range limit.
  3. Indoor unit sound levels are determined in an anechoic chamber at a distance of 1 metre from the front of the unit. They are normally higher during actual operation due to ambient noise.
  4. The current Energy Star Rating Scheme does not cover the determination of seasonal or part load efficiencies, which provide a better indication of efficiency under actual operating conditions. For this reason, the energy savings potential of inverter air conditioners is not reflected in the Star Rating.
  5. Inverter air conditioners do not have a current surge during start up. The compressor Start Current of an inverter air conditioner is typically the lower than specified Running Current.

Click here to open and close FTXG Specification Table


Floor Standing
R-410AStyle and comfort in a compact design

FVXS25F  FVXS35F    FVXS50F

FVXS Floor Standing

FVXS25F Cooling Capacity 2.5kW Heating Capacity 3.4kW FVXS35F Cooling Capacity 3.5kW Heating Capacity 4.5kW
FVXS50F Cooling Capacity 5.0kW Heating Capacity 6.0kW

HEATING & COOLING

INDOOR

 

FVXS25FV1A

FVXS35FV1A

FVXS50FV1A

OUTDOOR

 

RXS25EAVMA

RXS35EAVMA

RXS55OFAVMA

Rated Capacity
Cool (kW) 2.5 3.5 5.0
Heat (kW) 3.4 4.5 6.0
Capacity Range
Cool (kW) 1.3-3.0 1.4-3.8 1.4-5.6
Heat (kW) 1.3-4.5 1.4-5.0 1.4-8.1
Indoor Airflow Rate(Hi)
Cool (l/s) 136 141 178
Heat (l/s) 146 156 196
Indoor Fan Speed
  5 steps, quiet and automatic
Energy Label/
Star Ratings
Cool 6 5.5 5
Heat 6 5.5 4.5
Front Panel Colour
  White
Power Supply
  1 phase, 220-240V, 50Hz
Power Input
(Min-rated-max
Cool (kW) 0.30-0.57-0.92 0.30-1.02-1.25 0.5-1.55-2.0
Heat (kW) 0.29-0.79-1.39 0.31-1.22-1.88 0.5-1.76-26
C.O.P.
C/H 4.4/4.3 3.4/3.7 3.2/3.4
Dimensions
(H x W x D)
Indoor (mm) 600 x 700 x 210
Outdoor (mm) 550 x 765 x 285 735 x 825 x 300
Weight
Indoor (Kg) 14
Outdoor (Kg) 32 48
Compressor Type
  Hermetically sealed swing type
Refrigerant Type
  R410A
Max Pipe Length
(m) 20 30
Max Level Difference
(m) 15 20
Refrigerant Pipe Size
Liquid (mm) Ø6.4
Gas (mm) Ø9.5 Ø12.7
Drain (mm) Ø20
Operating Range
(outdoor temp)
Cool (CDB) 10 to 46°
Heat (CWB) -15 to 18 °
Indoor Sound
Level (H/L/SL)
Cool (dBA) 38/26/23 39/27/24 44/36/32
Heat (dBA) 38/26/23 39/27/24 45/36/32
Outdoor Sound
Level (H/L)
Cool (dBA) 46/43 47/44 47/44
Heat (dBA) 47/44 48/45 48/45
EPA Sound Power Level
Outdoor (dBA) 62 63 62

NOTES

  1. The Rated Capacity, Power Input and Running Current are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1
  2. The cooling (or heating) output capacity will be reduced below the rated value as the outdoor temperature approaches the maximum (or minimum) outdoor temperature operating range limit.
  3. Indoor unit sound levels are determined in an anechoic chamber at a distance of 1 metre from the front of the unit. They are normally higher during actual operation due to ambient noise.
  4. The current Energy Star Rating Scheme does not cover the determination of seasonal or part load efficiencies, which provide a better indication of efficiency under actual operating conditions. For this reason, the energy savings potential of inverter air conditioners is not reflected in the Star Rating.
  5. Inverter air conditioners do not have a current surge during start up. The compressor Start Current of an inverter air conditioner is typically the lower than specified Running Current.

Click here to open and close FVXS Specification Table


R-410AInverter Heating & Cooling - Cooling Only

FTKS25E  FTXS25E

FTKS25

FTKS25E Cooling Capacity 2.5kW
FTXS25E Cooling Capacity 2.5kW Heating Capacity 3.4kW

FTKS35E  FTXS35E

FTKS35

FTKS35E Cooling Capacity 3.5kW
FTXS35E Cooling Capacity 3.5kW Heating Capacity 4.0kW

COOLING ONLY

HEATING & COOLING

INDOOR

 

FTKS25EVMA

FTKS35EVMA

FTKS25EVMA

FTKS35EVMA

OUTDOOR

 

RKS25EVMA

RKS35EVMA

RKS25EVMA

RKS35EVMA

Rated Capacity
Cool (kW) 2.5 3.5 2.5 3.5
Heat (kW)     3.4 4.0
Capacity Range
Cool (kW) 1.2-3.0 1.2-3.8 1.2-3.0 1.2-3.8
Heat (kW)     1.2-4.5 1.2-5.0
Indoor Airflow Rate(Hi)
Cool (l/s) 145 148 145 148
Heat (l/s)     157 162
Indoor Fan Speed
  5 steps, quiet and automatic
Energy Label/
Star Ratings
Cool 6 5.5 6 5.5
Heat     6 5.5
Front Panel Colour
  White
Power Supply
  1 phase, 220-240V, 50Hz
Power Input
(Min-rated-max
Cool (kW) 0.30-0.60-0.80 0.30-1.02-1.20 0.30-0.60-0.80 0.30-1.02-1.20
Heat (kW)     0.29-0.83-1.34 0.29-1.08-1.55
C.O.P.
C/H 4.17 3.43 4.17/4.10 3.43/3.70
Dimensions
(H x W x D)
Indoor (mm) 283 x 800 x 195 283 x 800 x 195
Outdoor (mm) 550 x 765 x 285 550 x 765 x 285
Weight
Indoor (Kg) 9 9
Outdoor (Kg) 32 32
Compressor Type
  Hermetically sealed swing type
Refrigerant Type
  R410A
Max Pipe Length
(m) 20 20
Max Level Difference
(m) 15 15
Refrigerant Pipe Size
Liquid (mm) Ø6.4 Ø6.4
Gas (mm) Ø9.5 Ø9.5
Drain (mm) Ø18.0 Ø18.0
Operating Range
(outdoor temp)
Cool (CDB) 10 to 46° 10 to 46°
Heat (CWB)   -15 to 18 °
Indoor Sound
Level (H/L/SL)
Cool (dBA) 37/31/25/22 38/32/26/23 37/31/25/22 38/32/26/23
Heat (dBA)     37/33/28/25 38/34/29/26
Outdoor Sound
Level (H/L)
Cool (dBA) 46/43 47/44 46/43 47/44
Heat (dBA)     47/44 48/45
EPA Sound Power Level
Outdoor (dBA) 61 62 62 63

NOTES

  1. The Rated Capacity, Power Input and Running Current are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1
  2. The cooling (or heating) output capacity will be reduced below the rated value as the outdoor temperature approaches the maximum (or minimum) outdoor temperature operating range limit.
  3. Indoor unit sound levels are determined in an anechoic chamber at a distance of 1 metre from the front of the unit. They are normally higher during actual operation due to ambient noise.
  4. The current Energy Star Rating Scheme does not cover the determination of seasonal or part load efficiencies, which provide a better indication of effect under actual operating conditions. For this reason, the energy savings potential of inverter air conditioners is not reflected in the Star Rating.
  5. Inverter air conditioners do not have a current surge during start up. The compressor Start Current of an inverter air conditioner is typically the lower than specified Running Current.

Click here to open and close FTKS - FTXS Specification Table

R-410A FTKS50F  FTXS50F   FTKS60F   FTXS60F

FTKS50FFTKS50 External

FTKS50F Cooling Capacity 5.0kW
FTXS50F Cooling Capacity 5.5kW Heating Capacity 5.8kW
FTKS60F Cooling Capacity 6.0kW
FTXS60F Cooling Capacity 6.0kW Heating Capacity 7.0kW

FTKS71F FTXS71F   FTXS80F FTXS90F

FTKS71FFTKS71F External

FTKS71F Cooling Capacity 7.1kW
FTXS71F Cooling Capacity 7.1kW Heating Capacity 8.2kW
FTKS80F Cooling Capacity 8.0kW Heating Capacity 9.5kW
FTXS90F Cooling Capacity 9.0kW Heating Capacity 9.7kW

COOLING ONLY

HEATING & COOLING

INDOOR

 

FTKS50FVMA

FTKS60FVMA

FTKS71FVMA

FTKS50FVMA

FTKS60FVMA

FTKS71FVMA

FTKS80FVMA

FTKS90FVMA

OUTDOOR

 

RKS50FVMA

RKS60FVMA

RKS71FVMA

RXS50FAVMA

RXS60BVMA

RXS71FVMA

RXS80FVMA

RXS90FVMA

Rated Capacity
Cool (kW) 5.0 6.0 7.1 5.0 6.0 7.1 8.0 9.0
Heat (kW)       5.8 7.0 8.2 9.5 9.7
Capacity Range
Cool (kW) 1.7-6.0 1.7-6.7 2.3-8.5 1.7-6.0 1.7-6.7 2.3-8.5 2.3-9.0 2.3-9.7
Heat (kW)       1.7-7.7 1.7-8.0 2.3-10.0 2.3-10.2 2.3-11.0
Indoor Airflow Rate(Hi)
Cool (l/s) 245 270 290 245 270 290 352 352
Heat (l/s)       270 290 358 383 383
Indoor Fan Speed
  5 steps, quiet and automatic
Energy Label/
Star Ratings
Cool 5 4 4 5 4 4 3.5 3
Heat       5 4.5 4 3 2
Front Panel Colour
  White
Power Supply
  1 phase, 220-240V, 50Hz
Power Input
(Min-rated-max
Cool (kW) 0.44-1.55-2.08 0.44-1.98-2.39 0.57-2.36-3.20 0.44-1.55-2.08 0.44-1.98-2.39 0.57-2.36-3.20 0.57-2.86-3.50 0.57-3.30-3.97
Heat (kW)       0.40-1.60-2.53 0.40-2.04-2.81 0.52-2.52-3.75 0.52-3.28-3.82 0.52-3.54-4.18
C.O.P.
C/H 3.23 3.03 3.01 3.23/3.63 3.03/3.43 3.01/3.25 2.80/2.90 2.73/2.74
Dimensions
(H x W x D)
Indoor (mm) 290 x 1050 x 238 290 x 1050 x 238
Outdoor (mm) 735 x 825 x 300 770 x 900 x 320 735 x 825 x 300 770 x 900 x 320
Weight
Indoor (Kg) 12 12
Outdoor (Kg) 47 71 48 71
Compressor Type
  Hermetically sealed swing type
Refrigerant Type
  R410A
Max Pipe Length
(m) 30 30 30
Max Level Difference
(m) 20 20 20
Refrigerant Pipe Size
Liquid (mm) Ø6.4 Ø6.4 Ø6.4
Gas (mm) Ø12.7 Ø15.9 Ø12.7 Ø15.9 Ø15.9
Drain (mm) Ø20.0 Ø18.0 Ø20.0 Ø18.0 Ø18.0
Operating Range
(outdoor temp)
Cool (CDB) 10 to 46° 10 to 46° 10 to 46°
Heat (CWB)   -15 to 18 ° -15 to 18 °
Indoor Sound
Level (H/L/SL)
Cool (dBA) 44/40/35/32 45/41/36/33 46/42/37/34 44/40/35/32 45/41/36/33 46/42/37/34 49/45/40/37
Heat (dBA)       42/38/33/30 44/40/35/32 46/42/37/34 49/44/38/35
Outdoor Sound
Level (H/L)
Cool (dBA) 47/44 49/46 52/49 47/44 49/46 52/49 54/51
Heat (dBA)       48/45 49/46 52/49 54/51
EPA Sound Power Level
Outdoor (dBA) 61 63 66 62 63 66 68 68

NOTES

  1. The Rated Capacity, Power Input and Running Current are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1
  2. The cooling (or heating) output capacity will be reduced below the rated value as the outdoor temperature approaches the maximum (or minimum) outdoor temperature operating range limit.
  3. Indoor unit sound levels are determined in an anechoic chamber at a distance of 1 metre from the front of the unit. They are normally higher during actual operation due to ambient noise.
  4. The current Energy Star Rating Scheme does not cover the determination of seasonal or part load efficiencies, which provide a better indication of effect under actual operating conditions. For this reason, the energy savings potential of inverter air conditioners is not reflected in the Star Rating.
  5. Inverter air conditioners do not have a current surge during start up. The compressor Start Current of an inverter air conditioner is typically the lower than specified Running Current.
Click here to open and close FTKS50+ Specification Table

R-410AInverter Heating & Cooling - Cooling Only

FLXS35B   FLXS50B   FLXS60B

FLXS

FLXS35B Cooling Capacity 3.5kW Heating Capacity 4.0kW
FLXS50B Cooling Capacity 4.9kW Heating Capacity 6.1kW
FLXS60B Cooling Capacity 5.5kW Heating Capacity 6.9kW

R-22 FLK50A   FLK60A

FLK

FLK50A Cooling Capacity 4.7kW
FLK60A Cooling Capacity 5.7kW

HEATING & COOLING

COOLING ONLY

INDOOR

 

FLXS35BVMA

FLXS50BVMA

FLXS60BVMA

FLK50AVMA

FLK60AVMA

OUTDOOR

 

RXS35EAVMA

RXS50FAVMA

RXS60FVMA

RKD50BVMA

RKD60BVMA

Rated Capacity
Cool (kW) 3.5 4.9 5.5 4.7 5.7
Heat (kW) 4.0 6.1 6.9    
Capacity Range
Cool (kW) 1.2-3.8 1.7-5.3 1.7-6.5 0.9-5.3 0.9-6.5
Heat (kW) 1.2-5.0 1.7-7.5 1.7-8.0    
Indoor Airflow Rate(Hi)
Cool (l/s) 143 190 200 190 200
Heat (l/s) 163 202 213    
Indoor Fan Speed
  5 steps, quiet and automatic
Energy Label/
Star Ratings
Cool 4.5 3.5 4 5 3.5
Heat 4 4.5 2.5    
Front Panel Colour
  Almond White
Power Supply
  1 phase, 220-240V, 50Hz
Power Input
(Min-rated-max
Cool (kW) 0.30-1.08-1.23 0.44-1.72-1.95 0.44-1.88-2.62 0.45-1.47-1.95 0.45-1.99-2.67
Heat (kW) 0.29-1.23-1.85 0.40-1.82-2.63 0.40-2.40-3.24    
C.O.P.
C/H 3.24/3.25 2.88/3.35 2.93/2.88 3.20 2.86
Dimensions
(H x W x D)
Indoor (mm) 490 x 1050 x 200
Outdoor (mm) 550 x 765 x 285 735 x 825 x 300 735 x 825 x 300
Weight
Indoor (Kg) 16 17 17
Outdoor (Kg) 32 48 48 54
Compressor Type
  Hermetically sealed swing type
Refrigerant Type
  R410A R22
Max Pipe Length
(m) 20 30 30
Max Level Difference
(m) 15 20 20
Refrigerant Pipe Size
Liquid (mm) Ø6.4 Ø6.4
Gas (mm) Ø9.5 Ø12.7 Ø12.7 Ø15.9
Drain (mm) Ø20.0 Ø18.0
Operating Range
(outdoor temp)
Cool (CDB) 10 to 46° 10 to 46° -5 to 46°
Heat (CWB) -15 to 18 ° -15 to 18 °    
Indoor Sound
Level (H/L/SL)
Cool (dBA) 38/35/32/29 47/43/39/36 48/45/41/39 47/39/36 48/41/39
Heat (dBA) 39/36/33/30 46/41/35/33 47/42/37/34    
Outdoor Sound
Level (H/L)
Cool (dBA) 47/44 47/44 49/46 47/44 48/45
Heat (dBA) 48/45 48/45 49/46    
EPA Sound Power Level
Outdoor (dBA) 63 62 63 63 64

NOTES

  1. The Rated Capacity, Power Input and Running Current are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1
  2. The cooling (or heating) output capacity will be reduced below the rated value as the outdoor temperature approaches the maximum (or minimum) outdoor temperature operating range limit.
  3. Indoor unit sound levels are determined in an anechoic chamber at a distance of 1 metre from the front of the unit. They are normally higher during actual operation due to ambient noise.
  4. The current Energy Star Rating Scheme does not cover the determination of seasonal or part load efficiencies, which provide a better indication of effect under actual operating conditions. For this reason, the energy savings potential of inverter air conditioners is not reflected in the Star Rating.
  5. Inverter air conditioners do not have a current surge during start up. The compressor Start Current of an inverter air conditioner is typically the lower than specified Running Current.

Click here to open and close FTXS - FLK Specification Table

R-22 FTKD25D  FTKD35D

FTKD

FTKD25D Cooling Capacity 2.5kW
FTKD35D Cooling Capacity 3.5kW

FTKD50B   FTKD60B   FTKD71B

FTKD50B

FTKD50B Cooling Capacity 5.2kW
FTKD60B Cooling Capacity 4.9kW
FTKD71B Cooling Capacity 7.1kW

COOLING ONLY

INDOOR

 

FTKD25DVMA

FTKD35DVMA

FTKD50BVMA

FTKD60BVMA

FTKD71BVMA

OUTDOOR

 

RKD25DVMA

RKD35DVMA

RKD50BVMA

RKD60BVMA

RKD71BVMA

Rated Capacity
Cool (kW) 2.5 3.5 5.2 6.2 7.1
Heat (kW)          
Capacity Range
Cool (kW) 1.3-3.0 1.4-3.8 0.9-5.9 0.9-7.6 0.9-8.0
Heat (kW)          
Indoor Airflow Rate(Hi)
Cool (l/s) 148 150 280 292 305
Heat (l/s)          
Indoor Fan Speed
  5 steps, quiet and automatic
Energy Label/
Star Ratings
Cool 5.5 4.5 5 4 3
Heat          
Front Panel Colour
  White
Power Supply
  1 phase, 220-240V, 50Hz
Power Input
(Min-rated-max
Cool (kW) 0.31-0.73-1.03 0.31-1.13-1.37 0.45-1.60-2.30 0.45-2.10-3.21 0.45-2.60-3.35
Heat (kW)          
C.O.P.
C/H 3.42 3.10 3.25 2.95 2.73
Dimensions
(H x W x D)
Indoor (mm) 283 x 800 x 195 290 x 1050 x 238
Outdoor (mm) 550 x 765 x 285 735 x 825 x 300
Weight
Indoor (Kg) 9 12
Outdoor (Kg) 30 32 48 54 56
Compressor Type
  Hermetically sealed swing type
Refrigerant Type
  R22
Max Pipe Length
(m) 20 30
Max Level Difference
(m) 15 20
Refrigerant Pipe Size
Liquid (mm) Ø6.4 Ø6.4 Ø9.5
Gas (mm) Ø9.5 Ø12.7 Ø12.7 Ø15.9
Drain (mm) Ø18.0 Ø18.0
Operating Range
(outdoor temp)
Cool (CDB) 10 to 46° -5 to 46°
Heat (CWB)          
Indoor Sound
Level (H/L/SL)
Cool (dBA) 37/28/25 38/29/26 44/35/32 45/36/33 46/37/34
Heat (dBA)          
Outdoor Sound
Level (H/L)
Cool (dBA) 46/43 47/44 47/44 49/46 52/49
Heat (dBA)          
EPA Sound Power Level
Outdoor (dBA) 61 62 63 64 66

NOTES

  1. The Rated Capacity, Power Input and Running Current are determined under conditions T1 (cooling) or H1 (heating) of AS/NZS 3823.1.1
  2. The cooling (or heating) output capacity will be reduced below the rated value as the outdoor temperature approaches the maximum (or minimum) outdoor temperature operating range limit.
  3. Indoor unit sound levels are determined in an anechoic chamber at a distance of 1 metre from the front of the unit. They are normally higher during actual operation due to ambient noise.
  4. The current Energy Star Rating Scheme does not cover the determination of seasonal or part load efficiencies, which provide a better indication of efficiency under actual operating conditions. For this reason, the energy savings potential of inverter air conditioners is not reflected in the Star Rating.
  5. Inverter air conditioners do not have a current surge during start up. The compressor Start Current of an inverter air conditioner is typically the lower than specified Running Current.

Click here to open and close FTKD Specification Table


Inverter Power Control

Reluctance DC Motor

This motor achieves major increases in efficiency over conventional AC motors. Improvements of 20% have been realised in the low-frequency range where the air conditioner most often operates.

     
 Swing compressor Reluctance DC motor Pulse Amplitude Modulation

Uses 30% less energy a year than the ordinary method

  • The start and stop cycle is repeated less frequently, reducing energy loss at start-up.
  • As the room temperature nears the set temperature, capacity is automatically throttled down.
  • Operating efficiency is high because capacity is lowered to match the air temperature if the outside temperature becomes milder. For instance, when cooling, the energy saving effect is prominent when the outside air temperature drops below 30°C.

Heat / Cooling capacity up to 1.5 times that of ordinary methods

  • At start-up, heats or cools with up to 1.5 times higher full scale output than an ordinary air conditioner. Takes only 2/3 the normal time required to bring the room temperature to a pleasant level.

Less temperature fluctuation and greater comfort

  • Capacity is finely adjusted to match the changes in room temperature, providing constant comfort.

Flaps and louvres providing comfortable air current

This unique system directs warm air to the floor in winter and cool air upwards in summer for maximum efficiency and comfort. The large flap governs air flow directions while the small flap (or diffuser) swings, producing fine air currents that help circulate the air around the room.

Wide-Angle Louvres

These unique flexible louvres, with their innovative curved design, allow the air flow to be directed at angles of up to 60° from the centre, or 120° coverage.

 
about us what is
airconditioning?
quality equipment customer help technical 
information
testimonials office
locations
free design
 & quote
Head Office & Showroom: 109A Conyngham St, Frewville, South Australia 5063
Phone: 08 8379 7177             Fax: 08 8379 7166
© 2004 Affordable Airconditioning
Website by B & P THURSBY Digital Services