SkyAir

SkyAir Range

Product Line-up

Ceiling Mounted Cassette Type (Round Flow)

Compact Multi Flow Ceiling Mounted Cassette Type

Ceiling Suspended Type

Wall Mounted Type

Ceiling Mounted Built-in Type

Ceiling Mounted Slim Duct Type


Compact Multi Flow ceiling Mounted Cassette Type

Compact Multi Flow Quiet, decor-blending form and easy installation in new or old buildings.

Heat pump / Cooling only
FFQ25B8 / 35B8 / 50B8 / 60B8

Option: Accessory required for indoor unit

Wierd LCD RemoteWired LCD remote controller with weekly schedule timer.

BRC1D61

 

Wireless Remote Wireless LCD Remote controller

A signal receiver must be added to the indoor unit.

Heat pump BRC7E530W7
Cooling BRC7E531W7

Signal Receiver UnitSignal receiver unit
(installed type)

Wireless remote controller and signal receiver unit are sold as a set.

 

Compact Multi Flow Ceiling Mounted Cassette Type Specifications - Cooling Only

25 35 50 60
Model
Name
Indoor unit FFQ25B8V1B FFQ35B8V1B FFQ50B8V1B FFQ60B8V1B
Outdoor unit RKS25EVMA RKS35EVMA RKS50FVMA RKS60FVMA
Power Suppy
1 Phase, 220-240 V, 50 Hz
Cooling capacity1
Rated (Min. - Max.)
(kW) 2.5
(1.2-3.0)
3.4
(1.2-3.7)
4.7
(1.7-5.6)
5.8
(1.7-6.0)
Power Consumption
(kW) 0.73 1.10 1.62 2.065
Indoor
Unit
Colour
Unit
--
Decoration panel
White
Air flow rate (H)
ℓ/s 150/108 167/108 200/133 250/167
m3/min 9/6.5 10/6.5 12/8 15/10
Sound level (H/L)2
dB(A) 29.5/24.5 32/25 36/27 41/32
Sound power 3
dB(A) 46.5 49 53 58
Dimensions
(HxWxD)
Unit
mm 286x575x575 286x575x575 286x575x575 286x575x575
Decoration panel
mm 55x700x700 55x700x700 55x700x700 55x700x700
Machine weight
Unit
kg 17.5 17.5 17.5 17.5
Decoration panel
kg 2.7 2.7 2.7 2.7
Certified operation range
°CWB 14 to 28
Outdoor
unit
Colour
Ivory White
Compressor
Type
Hermetically sealed swing type
Motor output
kW 0.6 0.6 1.1 1.1
Refrigerant charge (R-410A)
kg 1.0
(Charged for 10 m)
1.0
(Charged for 10 m)
1.5
(Charged for 10 m)
1.5
(Charged for 10 m)
Sound level (H/L)2
dB(A) 47/44 47/44 47/44 49/46
Sound power 3
dB(A) 62 62 61 63
Dimensions (HxWxD)
(mm) 550x765x285 550x765x285 735x825x300 735x825x300
Machine weight
kg 32 32 48 48
Certified operation range
°CDB 10 to 46
Piping
connections
Liquid (Flare)
mm Ø6.4 Ø6.4 Ø6.4 Ø6.4
Gas (Fare)
mm Ø9.5 Ø9.5 Ø12.7 Ø12.7
Drain
Indoor unit
mm VP20 (I.DØ20xO.DØ26)
Outdoor unit
mm Ø18.0 (Hole) Ø18.0 (Hole) Ø18.0 (Hole) Ø18.0 (Hole)
Max. interunit piping length
m 20 30
Max. installation level difference
m 15 20
Heat insulation
Both liquid and gas piping

NOTES

  1. Rated cooling capacities are based on the following conditions: Indoor temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB Equiv. refrigeration piping, 7.5 m (horizontal).
  2. Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  3. Numerical values are according to ISO 3741:1999.

 

Ceiling Mount Slim Duct Type

Ceiling Mounted Slim Duct TypeSuitable for tight ceiling spaces.

Heat pump
FDXS25/35/50/60CVMA

Smooth Finish

The only visible sign of these unobtrusive units is their discgarge grilles. They fit completely inside the ceiling to maintain the original decor of a room. Each unit comes with its own wireless remote controller.

Slim Profile

The new series adds a 2.5 kW model. All units share the same low height of just 200 mm. This means it is now possible to install a unit inside a shallow ceiling cavity with a height of just 240 mm.

Quiet Operation

Indoor Unit Quiet Operation provides a low sound level ob 31 dB and POutdoor Unit Quiet Operation provides a low sound of 47* dB for new FDXS25C.

*During cooling operation

Ceiling Mount Slim Duct Type Specifications

25 35 50 60
Model
Name
Indoor unit FDXS25CVMA FDXS35CVMA FDXS50CVMA FDXS60CVMA
Outdoor unit RXS25EAVMA RXS35EAVMA RXS50FAVMA RXS60FAVMA
Power Suppy
1 Phase, 220-240 V, 50 Hz
Cooling capacity1
Rated (Min. - Max.)
(kW) 2.4
(1.2-3.0)
3.4
(1.2-3.8)
5.0
(1.7-5.3)
6.0
(1.7-6.5)
Heating capacity2
Rated (Min. - Max.)
(kW) 3.2
(1.2-4.5)
4.0
(1.2-5.0)
5.8
(1.7-6.0)
7.0
(1.7-8.0)
Power Consumption
Cooling1
(kW) 0.69 (0.3-0.92) 1.09 (0.3-1.27) 1.65 (0.44-1.93) 2.13 (0.44-2.49)
Heating2
(kW) 0.91 (0.29-1.49) 1.18 (0.29-1.79) 1.92 (0.4-2.04) 2.32 (0.4-3.18)
Indoor
Unit
Colour
--
Air flow rate (H/L)
ℓ/s 158/133 167/142 200/167 266/225
m3/min 9.5/8 10/8.5 12/10 16/13.5
Fan
External static pressure
Pa(mmH2O) 40 40 40 40
Driving system
 
Sound level (H/L)3
dB(A) 35/31 35/31 37/33 38/34
Sound power (H/L)4
dB(A) -- -- -- --
Dimensions
(HxWxD)
mm 200x900x620 200x900x620 200x900x620 200x1,100x620
Machine weight
kg 25 25 27 30
Certified operation range
°CWB 14 to 28
°CDB 10 to 30
Outdoor
unit
Colour
Ivory White
Compressor
Type
Hermetically sealed swing type
Motor output
kW 0.6 0.6 1.1 1.1
Refrigerant charge
(R-410A)
kg 1.0
(Charged for 10 m)
1.0
(Charged for 10 m)
1.5
(Charged for 10 m)
1.5
(Charged for 10 m)
Sound level
Cooling/Heating3 dB(A) 47/48 47/48 47/48 49/49
Sound power
Cooling/Heating4 dB(A) 62/63 62/63 61/62 63/63
Dimensions (HxWxD)
(mm) 550x765x285 550x765x285 735x825x300 735x825x300
Machine weight
kg 32 32 48 48
Certified operation range
Cooling °CDB 10 to 46 10 to 46
Heating °CWB -10 to 20 -15 to 18
Piping
connections
Liquid (Flare)
mm Ø6.4 Ø6.4 Ø6.4 Ø6.4
Gas (Flare)
mm Ø9.5 Ø9.5 Ø12.7 Ø12.7
Drain
Indoor unit
mm VP20 (I.DØ20xO.DØ26)
Outdoor unit
mm Ø18.0 Ø18.0 Ø18.0 Ø18.0
Max. interunit piping length
m 20 30
Max. installation level difference
m 15 20
Heat insulation
Both liquid and gas piping

NOTES

  1. Rated cooling capacities are based on the following conditions: Suction temp., 27°CDB, 19.0°CWB; outdoor temp. 35°CDB Equiv. refrigeration piping, 7.5 m (horizontal).
  2. Rated heating capacities are based on the following conditions: Suction temp., 20 °CDB; outdoor temp., 7°CDB, 6°CWB. Equiv. refrigeration piping, 5 m (horizontal).
  3. Anechoic chamber conversion value, measured according to JIS parameters and criteria. During operation these values are somewhat higher owing to ambient conditions.
  4. Numerical values are according to ISO 3741:1999.

 

 
about us what is
airconditioning?
quality equipment customer help technical 
information
testimonials office
locations
free design
 & quote
Head Office & Showroom: 109A Conyngham St, Frewville, South Australia 5063
Phone: 08 8379 7177             Fax: 08 8379 7166
© 2004 Affordable Airconditioning